Fresenius Vial Pilot A2 Medical Infusion Syringe PumpFresenius
Pilot A2
Fresenius Vial Pilot A2 Medical Infusion Syringe Pump
Fresenius
Pilot A2
VB acresce IVA
243 €
Condição
Usado
Localização
Borken 

Dados básicos
- Designação da máquina:
- Fresenius Vial Pilot A2 Medical Infusion Syringe Pump
- Fabricante:
- Fresenius
- Modelo:
- Pilot A2
- Condição:
- usado
Preço e localização
VB acresce IVA
243 €
- Localização:
- Borken, Alemanha

Ligar
Detalhes da oferta
- ID do anúncio:
- A23232010
- Número de referência:
- 74854
- Atualização:
- por último em 28.10.2026
Descrição
Fresenius Pilot A2 Syringe Pump
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
In everyday medical practice, the device is used for the continuous, precisely controlled administration of highly effective medications, anesthetics, or infusion solutions via standard syringes.
The device features a clear control panel, a digital display for rate indication, and automatic safety and alarm functions.
Bjdpfo Af Uumsx Ahdoww
Thanks to the pre-mounted, robust original bracket on the back, the pump can be quickly and securely attached to infusion stands, intensive care beds, or standardized medical rails.
Features:
- High flexibility: Automatic detection and compatibility with common 20 ml and 50 ml Luer-Lock syringes (pre-settings for BD Plastipak, Braun Perfusor, and Monoject can be read directly on the housing).
- Clear control panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for accurate rate indication.
- Comprehensive safety system: Visual and audible pre- and main alarms for occlusion, incorrect syringe positioning, power failure, or low battery.
- Mobility: Integrated battery for bridging patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Flow rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1% (drive mechanism), ± 2% (syringe)
Power supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety features: Audible and visual alarm systems (e.g., for occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2014
"Everything from a single source: We would be happy to offer you suitable bank financing for your project."
You can find more new and used items in our shop!
International shipping costs on request!
O anúncio foi traduzido automaticamente. Podem ocorrer erros de tradução.
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
In everyday medical practice, the device is used for the continuous, precisely controlled administration of highly effective medications, anesthetics, or infusion solutions via standard syringes.
The device features a clear control panel, a digital display for rate indication, and automatic safety and alarm functions.
Bjdpfo Af Uumsx Ahdoww
Thanks to the pre-mounted, robust original bracket on the back, the pump can be quickly and securely attached to infusion stands, intensive care beds, or standardized medical rails.
Features:
- High flexibility: Automatic detection and compatibility with common 20 ml and 50 ml Luer-Lock syringes (pre-settings for BD Plastipak, Braun Perfusor, and Monoject can be read directly on the housing).
- Clear control panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for accurate rate indication.
- Comprehensive safety system: Visual and audible pre- and main alarms for occlusion, incorrect syringe positioning, power failure, or low battery.
- Mobility: Integrated battery for bridging patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Flow rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1% (drive mechanism), ± 2% (syringe)
Power supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety features: Audible and visual alarm systems (e.g., for occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2014
"Everything from a single source: We would be happy to offer you suitable bank financing for your project."
You can find more new and used items in our shop!
International shipping costs on request!
O anúncio foi traduzido automaticamente. Podem ocorrer erros de tradução.
Fornecedor
Nota: Registe-se gratuitamente ou faça login, para aceder a todas as informações.
Registrado desde: 2008
532 Anúncios online
Enviar pedido
Telefone & Fax
+49 2862 ... anúncios
Estes anúncios também podem ser do seu interesse.
Com êxito
A sua mensagem foi enviada.
Anúncio classificado
Borken
1 810 km
Bomba de seringa para infusão médica Fresenius Vial Pilot A2, Perfusor C
FreseniusPilot A2
FreseniusPilot A2
Com êxito
A sua mensagem foi enviada.
Anúncio classificado
Borken
1 810 km
Bomba de infusão por seringa médica Fresenius Vial Pilot A2, perfusor b
FreseniusPilot A2
FreseniusPilot A2
O seu anúncio foi eliminado com sucesso
Ocorreu um erro